HD LCD Display, high capacity words, friendly user interface, dynamically display working status.
Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting, etc.
Compatible with 5ml, 10ml, 20ml, 30ml, 50/60ml syringe of any brands;
Preset solution volume to greatly reduce the workload of nurses;
Three working modes: Rate mode, Time Volume mode, Dosage Weight mode;
Three levels of occlusion: high, medium, and low;
KVO (keep-vein-open) automatically opens as injection is completed, KVO rate is 0.1-5ml/h(0.1ml/h step);
Freely Stackable: freely stack one syringe pump onto another to provide multiple solutions, which have a wide range of clinical applications.
Model | BYZ-810 | BYZ-810D |
Screen | HD LCD Display | HD LCD Display |
Work modes | 3 Work modes: | 3 Work modes: |
UI | English, Chinese, Russian can customize the language | |
Quick start, rapid installation | ||
Auto-lock screen | ||
Night mode optional | ||
Syringe set | 5ml, 10ml, 20ml, 30ml, 50/60ml | |
Syringe size detection | Autodetect syringe size | |
INFUSION rate range | 0.1ml/h~1500ml/h (0.1ml/h step) | |
Volume to be infused (VTBI) | 0.1---9999.9ml (0.1ml step) | |
Nominal flow rate accuracy | Within ±3% | |
Purge/Bolus | KVO, Bolus, Purge, Anti-bolus | |
KVO Rate | 0.1~5ml/h (0.1ml/h step) | |
Obstruct pressure monitoring | 3 Levels | |
CPU | Dual microprocessor controlled | |
Medicine Library | NO | 1000 drugs |
History | NO | 2000 record |
Power | 100-240Vac, 50/60Hz; 4 hours backup time; DC 12V 2A optional |
Model | BYZ-810 | BYZ-810D |
Image | ||
Screen | HD LCD Display | HD LCD Display |
WiFi module | NO | NO |
Communicate with Host | NO | NO |
Work modes | 3 Work modes: | 3 Work modes: |
Compatible dock station | NO | NO |
UI | English, Chinese, Russian can customize the language | |
Quick start, rapid installation | ||
Auto-lock screen | ||
Night mode optional | ||
Syringe set | 5ml,10ml,20ml,30ml,50/60ml | |
Syringe size detection | Autodetect syringe size | |
INFUSION rate range | 0.1ml/h~1500ml/h (0.1ml/h step) | |
Volume to be infused (VTBI) | 0.1---9999.9ml (0.1ml step) | |
Nominal flow rate accuracy | Within ±3% | |
Purge/Bolus | KVO, Bolus, Purge,Anti-bolus | |
KVO Rate | 0.1~5ml/h (0.1ml/h step) | |
Obstruct pressure monitoring | 3 Levels | |
IP level | IPX2 | |
Alarm | Audible and Visible Alarms | |
CPU | Dual microprocessor controlled | |
Medicine Library | NO | 1000 drugs |
History | NO | 2000 record |
Power | 100-240Vac, 50/60Hz; 4 hours backup time; DC 12V 2A optional |