Neonatal Ventilator is a special ventilator which is used for newborn. Below several situations happening, we use the neonatal ventilator: treat hypoventilation, suitable for children with severe hypoventilation; Improve ventilation function, suitable for children with severe ventilation disorder; Increase heart reserve capacity, suitable for the newborn who did the chest and heart surgery.
Designed for newborns, NV Series Ventilator offers a professional non-invasive nasal ventilation mode with advanced apnea wake-up function, automatic leak compensation function, and so on.
NV Series Ventilator is an all-in-one non-invasive ventilation solution with PIP (Peak Inspiratory Pressure) as high as 20cmH2O. The comprehensive ventilation modes and pressure performance help ensure that newborns can avoid tracheal intubation.
Clinical studies have proven that NIPPV/SNIPPV mode can effectively reduce intubation rate and increase the success rate of invasive ventilation withdrawal.
The comprehensive and leading non-invasive ventilation mode provides more choices for clinical care.
Equipped with NV8 NV Flow /Neo. Flow pressure generator, which is safe, comfortable and features good sealing performance fully compatible with infant flow/infant flow LP/medijet and other brands to meet different clinical needs.
A wide range of nasal plugs and nasal masks to meet the needs of premature babies and infants.
Monitor all the time and respond to apnea with intelligent synchronization.
The NV Series provides reliable respiratory monitoring through an abdominal respiratory sensor, and the NCPAP mode features an apnea wake-up function, which effectively reduces the incidence of apnea.
With 10 levels of sensitivity settings, the accuracy of breathing synchronization in SNIPPV mode can reach more than 90%.
Clear and bright 8-inch LED screen, touch operation, clearly visible from any angle and distance, 15° tilt screen, larger viewing angle, ergonomic, intuitive settings to reduce human error, and allows doctors to focus on newborns.
Parameter | Adjustable Range | Step Size | Work Mode |
CPAP | 1~13 cmH2O | 1~3 cmH2O: 0.2cmH2O | NCPAP |
Peep | 1~13 cmH2O | NIPPV, SNIPPV | |
Pinsp | 3~15 cmH2O | 3~8cmH2O: 0.5cmH2O | NIPPV, SNIPPV |
Papnea | NCPAP | ||
Manual vent | |||
Flow | 0.5~20L/Min | 0.5~2L/Min: 0.1L/Min | HFNC |
Manual vent | 3~25L/Min | 23~10L/Min: 0.5L/Min | NCPAP, NIPPV, SNIPPV, HFNC |
O2% | 21~100% | 10%0~205L/Min: 1L/Min | NCPAP, NIPPV, SNIPPV, HFNC |
Flush O2 | ±3% of the set value | ||
Rate | ±0.5 bpm or ±1% of the set value | ||
Rb | ±0.5 bpm or ±1% of the set value | ||
Ti | set value ±0.005s | ||
Flow | Flow: ±0.2L/Min or ±5% of the set value, whichever is greater. | ||
Tapnea | Error: ±al0v.1esntilation: ±0.2L/Min or ±5% of the set value, | ||
Measuring Parameters | |||
O2% | ±2% of the actual reading | ||
CPAP / PEEP | ±0.2cmH2O or ±2% of the actual reading, whichever is greater. | ||
Ppeak | |||
Pmean | |||
Rsp | ±1 respiration/min or ±5% of the actual reading, whichever is greater. | ||
Flow | ±0.2L/Min or ±5% of the set value, whichever is greater. |