ALL TRUSTED MEDICAL  LTD
ALL TRUSTED MEDICAL  LTD
  • MA-688 Quantstudio Pcr Machine

MA-688 Real-Time Quantitative Thermal Cycler

  • Excellent temperature control performance: High quality semiconductor thermoelectric module, combined with German high-end PT1000 temperature sensor and edge thermal compensation temperature.

  • Super multi-purpose function: Peltier Base heating module with multi-point temperature control can provide gradient temperature function of optimization experiment.

Key Features of MA-688 Real-Time Quantitative Thermal Cycler

  • Extraordinary optical design

    Maintenance-free LED excitation light source, the fluorescence signal of high temperature resistant professional fiber real-time transmission of 48-hole, high signal-to-noise ratio photodiode reading signal, ensure no edge effect.

  • Friendly, intuitive software setup interface

    Quick response parameter setting wizard, intuitive sample setting wizard, powerful experimental data analysis function.

  • Fast lab start and report output

    It does not need preheating and is easy to operate on and off, and can be used for experiments in the 30s. Intelligent data analysis, report output can be completed within 10 minutes.


Technical Specifications of MA-688 Real-Time Quantitative Thermal Cycler

Tube capacity

48*0.2ml

Sample volume

20-120ul

Apply consumables

0.2ml PCR tube. 8*0.2ml PCR tube

Temperature control range

4℃~99℃

Temperature accuracy

<0.1℃

Temperature uniformity

<±0.25℃

Heating speed

4.5℃/S

Cooling speed

3℃/S

Heating cooling

Semiconductor mode

Hot cover

Electric heat cover

Fluorescence detection system performance

Light source

High brightness LED

Detector

PD

Excitation and detection of propagation media

High temperature resistant professional fiber

The linear range of samples

I00-109copies

Sample linearity

R>0.99

Sample testing   repeatability

CV<1.00%

Excitation wavelength

The first channel: 470nm±10nm

The second channel: 525nm± 10nm

The third channel: 570nm±10nm

The fourth channel:  620nm± 10nm

Detection wavelength

The first channel: 520nm±10nm

The second channel: 570nm±10nm

The third channel: 620nm±10nm

The fourth channel: 670nm±10nm